Room Cooling
Room cooling is most widely used in the fruit industry
when post-harvest respiration is slow enough that quality
loss is very small. Growers of apples and melons often employ
room cooling. Good fan design and location to provide optimum
circulation of air is essential to room cooling.
Portable Units
Forced-air cooling units can be designed to fit
within a standard 40-foot (ca. 12 m) sea container. Although
auxiliary refrigeration is required, these units can be towed
to remote sites and operated with no set-up needed. Other
portable units can be used as centralized sources of cold
air refrigeration and movement.
Forced-air Cooling Equipment Features:
● Available in capacities
of 2 to 20 pallet (1.5 MT to 15 MT)
● All aluminum or optional stainless
steel cabinet, discharge hood and defrost pans equipped
with efficient drainage connections.
● Maximum span on evaporator coil to
maximize heat transfer, reduce cycle time
● Operations simplified for maximum
consistency and efficiency with adjustable cycle timers,
Green refrigeration components or ammonia refrigeration
systems available
● Optional reverse-pitch fans provide
rapid temperature pull-down with reduced noise levels.
● Humidification and semi-automatic
tarp handling equipment available
Considerations in the Selections of Forced-air
or Pressure Cooling
Advantages:
● Inexpensive options are available
for small farms
● Cooling can take place in containers
packed and ready for distribution
● Especially good with products that
have low respiration rate
● Systems can handle large volumes
and large containers
Disadvantages
● Moisture and weight loss can be problems
● For sensitive products, humidification
systems are required
● Not suitable for many products, especially
where respiration rate is high
Containers and Stacking Considerations
for Forced-air Cooling
Many types and sizes of fresh produce containers
can be used successfully with forced-air cooling. Popular
types include fiberboard cartons; and unlined plastic containers,
including large bins. The containers should stack together
tightly so that the air must flow through the openings in
walls of the container and thence the produce. The openings
must be designed with size and arrangement to ensure that
the produce in inside does not block the air flow. The ratio
of orifices to container surface should be at least 5%. Placement
must consider air flow and the effect on container strength.
Back
|